(949) 733-9635 | Se habla español! |  

Diagnostic

DiagnosticBanner

We carry only the best diagnostic equipment from leading manufacturers.

DiagnosticLogos

  • Optovue RTvue OCT System

    RTVue is an ultra-high speed, high resolution OCT retina scanner used for retina imaging and analysis. It is based on the next generation Fourier-Domain Optical Coherence technology just emerging from clinical research in the last two years. The ultra-high speed and high resolution features enable the FD-OCT to visualize the retinal tissue with ultra-high clarity in a fraction of seconds.

  • Topcon 3D OCT-2000 Spectral Domain OCT

    The Topcon 3D OCT-2000 System is the first Spectral Domain OCT system to incorporate a high resolution fundus camera and a user friendly color touch screen display in a compact, space saving design.  The easy-to-use, intuitive FastMap™ software enables dynamic viewing of the OCT data, providing 3D, 2D and fundus images simultaneously.  Pin-Point™ Registration properly indicates the location of the OCT image within the fundus image.  In addition, the compare function allows users to view serial exams in a comparison view and apply different analytical tools.  The seamless integration of the 3D OCT-2000 with Topcon’s Synergy™ Ophthalmic Data Management System provides true connectivity and access to images anywhere, anytime.

  • Zeiss Cirrus 4000 HD OCT Tomographer

    Cirrus 4000 HD OCT! Complete system and the latest OCT offered from Zeiss. This HD interface is very efficient, easy to use and will network with many other Ziess products. The Cirrus 4000 is one of the fastest OCTs on the market.

    Cirrus HD optical coherence tomography instrument uses spectral domain technology to capture exquisite volumetric (3D) & high definition line scans of the retina for precise detail of retinal tissue and pathology. The Cirrus has advanced hardware and software that facilitate automated alignment and high patient through-put. An elegant user interface and fast electronics mean chair time is shortened. The Cirrus HD-OCT realizes the superior capabilities of ZEISS optics and provides exquisite high definition images and analyses for enhanced clinical confidence. It provides beautiful high definition OCT scans and LSO fundus images providing visualization of retinal structure. HD layer maps and thickness maps reveal the critical details of histology and pathology at a glance.

  • Zeiss Stratus OCT-III Tomographer w. 7.0

    This Carl Zeiss OCT III Stratus is now available with the newest 7.0 software. The Stratus OCT is by far the best value OCT on the market. Great scans, quality image and easy to use all at a very affordable price. Our units are fully refurbished and in stellar condition.

    This Carl Zeiss OCT III Stratus is now available with the newest 7.0 software upgrade!!

    The OCT-III Stratus is an imaging device that provides direct cross sectional images of the retina for objective measurement and subjective clinical evaluation.

    The OCT-III Stratus:

    • Used in glaucoma detection and retinal disease.
    • Images and analyzes macular thickness.
    • Instrument offers 3 diagnostic capabilities; Macula, RNFL, and Optic Nerve Head.
  • Zeiss 740 Visual Field Analyzer Perimeter

    The Humphrey 740 Visual Field Machine is a very reliable, yet affordable visual field. The 740 performs most tests flawlessly and at at an acceptable speed. Our units are sold fully refurbished, inspected and upgraded. Our visual fields are also sold with the Zeiss power table with integrated printer.

    The Humphrey 740 perimeter includes 19 test patterns, user designed custom testing capability with a testing range out to 90 degrees. A 1.1GB hard disk storage is provided, eliminating the need for an external computer. SITA, the expert operating system, is an optional feature on the model Humphrey 740. Fastpac software is included reducing testing time by 40%. multiple statpac test results can be printed to compare visual field progression over time. Foveal threshold testing, stimulus sizes from Goldman I-V and stimulus colors in Red and blue are included. IOP, C/D, and user comments can be entered on the printout. A VGA monitor hook up for FHA screen viewing outside the perimetry room is built in.

  • Zeiss 750 Visual Field Analyzer Perimeter

    The Humphrey Zeiss 750 perimeter includes all of the previous features plus head tracking with automatically aligns the patients head during the test, keeping the eye aligned in the trial lens. Automatic vertex monitoring alerts the operator when the patient backs away from the instrument. Automatic pupil measurement accurately measures the pupil size. A 1.1 GB hard drive with streamer tape backup is provided for increase storage capacity and patient data backup security. Blue- Yellow testing and key board are standard on the model Humphrey 750 perimeter. Free future enhancements include STATPAC for Blue- Yellow, Kinetic testing, and custom testing.

  • Sonomed Escalon 300A+ PacScan Plus A Scan

    The PacScan Plus 300A+ offers a portable, digital A-scan , with a large color touch screen, on-board memory and USB interface for EMR archiving, extreme accuracy, repeatable measurements and reliability. The combination of a high frequency, low noise probe and fast precise algorithm enables scan capture immediately upon application of the probe along the visual axis.

    The PacScan Plus A-Scan offers built-in immersion capabilities and up to nine IOL formulas, including three post-refractive formulas. Axial length, ACD, and lens thickness are provided for each scan. Group up to five scans with average axial length and standard deviation automatically calculated. Easily review each scan, delete outlying scans, and add new scans, as desired. Customizable tissue velocities of each structure and highly-developed automatic scan recognition algorithms ensure accurate and repeatable measures. Built-in calibration check ensures continued accuracy of system.

  • Sonomed Micropach 200P Pachymeter

    Sonomed Pachymeter measures the thickness of the cornea using preprogrammed corneal maps. The 200P+ Micropach offers a portable, digital pachymeter, with extreme accuracy, repeatable measurements and reliability. The combination of the low noise probe and fast precise algorithm enables automatic scan capture immediately upon steady application of the probe onto the cornea.

    Measurement accuracy and repeatability are assured by each scan actually consisting of 256 individual measurements and an automatic measurement algorithm to ensure that only scans with proper probe alignment are accepted. Multiple corneal maps are available, with ability to group up to five scans at each point.

  • Konan CellChek XL Specular Microscope System

    Simple to use
    The CellChek XL specular microscope represents the latest in endothelial cell analysis, algorithms, and computer technology. Enhanced with auto-focus, auto-alignment, and auto-cell counting, the CellChek XL easily captures consistent, high quality images of the patient’s corneal endothelium using a patented method that identifies the position of the cellular interface.

    Powerful multi-point, analytic detail
    The CellChek XL offers five fixation points for image capture at the center and four peripheral sites, allowing a more comprehensive look at the cornea. This is particularly valuable in cases such as keratoconus | corneal transplantations, DSAEK, CXL, or the presence of corneal dystrophies.

    Location specific data samples
    Unique to the CellChek XL, the CellChek™ software automatically records the location from which the data samples were acquired. One strong value of specular microscopy is to be able to assess and quantify change in the cornea over time. Without location data,trending is simply not accurate or reliable.

    Advanced database features
    Fully integrated database management system allows robust data mining and simplification of links to electronic medical records.

    Non-contact pachymetry
    Using non-contact optical pachymetry, the CellChek XL provides corneal thickness measurements at all five data sample sites. Independent studies have shown this to be more accurate than traditional ultrasoundpachymetry.1

    The only FDA 510(k) cleared specular microscope (“NQE”)

    Konan is the only company to have products FDA 510(k) cleared under “Specular Microscopes” Product Code NQE. Why accept anything less than the assurance of the FDA’s review for both imaging and assessment of the corneal endothelial cell layer, morphology of endothelial cells, and corneal pachymetry.

  • Tomey SM 3000 Specular Microscope

    Easy photographing using the touch alignment function. Simply touching the center of the pupil displayed on the screen centers the image.
    You can then take photos immediately with the Auto Alignment and Auto Shot functions by lightly pressing the center of the screen and moving the measuring head toward the patient’s eye.

    Touching the eye display button automatically moves the measuring head to the other eye, so the patient does not need to move their face.

    Serial photographs of 15 shots
    15 shots can be taken in series and errors during photographing are reduced. In addition, the best image among the shots is automatically selected and displayed on the screen.

    Wide photographing range and 7 capturing positions
    Our unique technology enables a wide photographing range of 0.25 x 0.54 mm and allows you to observe the endothelium over a wide range.
    Photos can be taken at 7 points: the center and 6 peripheral points (2, 4, 6, 8, 10, and 12-o’clock positions on a 0 6 mm arc). Because there are many photographing points, you can select the point with the best conditions even when the cornea surface is irregular. The cornea thickness is also measured at the same time.

    Quick and automatic analysis of corneal endothelium cells
    The software for automatic analysis is pre-installed, so images are analysed automatically without personal computers.

    Manual photographing is also available
    When automatic photographing is difficult, you take photos manually using the power joystick.

    LED light source
    A long-life LED has been introduced for the photographing light source instead of the conventional xenon lamp, which requires maintenance. Regular replacement of the lamp is a thing of the past.
    USB connector for printer and LAN connector for PC
    USB-D connector: Connected to a Pict Bridge compatible printer to print images of the corneal endothelium and analysis results
    USB-H connector: Connected to a barcode reader or electromagnetic card reader to enter patient ID data. A digital printer may also be connected
    LAN connector: After installing the “Data Transfer” software provided with the EM-3000 in your personal computer, inspection result files assigned a patient ID can be saved in the personal computer.

  • CANON CR-1 Mark II Digital Fundus Camera

    The Canon CR-1 Mark II Digital Retinal Camera epitomizes state-of-the-art non-mydriatic imaging technology with dramatically reduced brightness, improved overall comfort, and significantly shorter exams. For patients having non-mydriatic retinal exams, the bright flash can be unpleasant. The CR-1 Mark II focuses on reducing patient stress to provide comfortable retinal exams by significantly reducing the flash intensity. Because retinal exams play an important role in screening for major illnesses, the ease of examining provided by the CR-1 Mark II supports overall healthcare for people.

  • Topcon TRC-50IX Mydriatic Retinal Camera

    Topcon TRC-50IX The ultimate camera for all photographic applications! This tri-functional camera sets the standard for ICG, fluorescein, and color imaging, and is designed with the added flash settings necessary for today’s sensitive digital cameras. A large eyepiece and alignment dots enable the photographer to easily and comfortably align the camera. Superior optical coatings eliminate flare and assure maximum image quality.

  • Zeiss Visucam Pro Non-Mydratic Fundus Camera
    • Smallest pupil size capture capability – minimum pupil diameter requirement is 3.3 mm
    • Ergonomic design, compact and easy to operate software to quickly capture and display images – Reduced user training time equals more efficient work flow in an all-in-one imaging system
    • Network ready and DICOM conformant – Advanced integration of hardware and software
    • Medical-grade imaging sensor and ZEISS Autoflash – Brilliant true color retinal images, perfectly exposed every time
    • ZEISS telecentric optics – Provides the highest level of optical purity, image accuracy, and quality
  • Zeiss IOL Master Version 3

    This IOL Master is a complete system including the Zeiss power table, manual, calibration tool and all accessories. Our technician ensures these units are not only working flawlessly, but look flawless too. The Zeiss IOL Master Version 3 is a true workhorse and will provide you with reliable, consistant results.

    A non-contact optical device that measures the distance from the corneal vertex to the retinal pigment epithelium by partial coherence interferometry, the IOL Master is consistently accurate to within ±0.02 mm or better.  Our trained technician refurbishes our IOL Masters to perfection.  The Zeiss Power Table is included along with a full warranty.

  • Zeiss IOL Master Version 500

    The ZEISS IOLMaster® 500 is the gold standard in optical biometry with more than 100 million successful IOL power calculations to date. With the new version of the ZEISS IOLMaster 500, you get a piece of cutting-edge technology that points the way to the future of optical biometry. Unique ULIB data set

    Improving refractive outcomes

    Any intraocular lens calculation is only as reliable as the lens constant it is based on. More than 40,000 sets of patient data created with the ZEISS IOLMaster are the basis of more than 200 optimized lens constants in the User Group for Laser Interference Biometry (ULIB) website – absolutely unique in the industry. Together with its one-of- a-kind distance independent telecentric keratometry and the exclusively integrated Holladay 2 formula, the gold standard in optical biometry helps you improve your refractive outcomes.

    Markerless toric IOL alignment

    The new Option Reference Image is the starting point of a markerless toric IOL workflow: an image of the eye is taken along with the keratometry measurement. Both, reference images and keratometry data are transferred to the ZEISS CALLISTO eye® computer-assisted surgery system. Finally, all data needed for precise and markerless toric IOL alignment is injected into the eyepiece of the surgical microscope from ZEISS.

    Advanced measurement of challenging eyes

    The true test of a biometer is its performance with challenging eyes. In denser cataracts, the ZEISS IOLMaster 500 achieves a measurement success ratio that is up to 20% higher than that of other optical biometry devices. Even with staphyloma, pseudophakic and silicone-filled eyes, the ZEISS IOLMaster 500 measures along the visual axis, yielding the relevant axial distance. And with its Haigis-L formula on board the ZEISS IOLMaster 500 is dedicated to myopic and hyperopic post-LVC cases.

    The results of a meta-analysis of 28 published clinical papers covering more than 1900 cases show that the reported clinical outcomes for the ZEISS IOLMaster with regard to residual astigmatism “[…] exceed, or are at least as good as those using manual or automated keratometry.”

    Toric IOL studies report excellent outcomes using IOLMaster keratometry.

    Ease of use

    A well-designed user interface, plausibility checks, distance-independent measurements and an up to 4 times faster reading compared to other optical devices lead to a one-of-a-kind usability and reduced chairtime. A difference you, your team and your patients will notice every day.

 